Inputs Screen
1. Inputs 1–7 must have the Continuous Audio Message box selected. This allows the message to
play while the input is active and stop when the input is inactive. Input control lines are supplied
from the M/I cabinet’sExternal Interface PCBA. A reset input to the AMI is not required. See
screen shot below for example of Input 1. Duplicate these settings for inputs 2–7.
2. Change the Current Output Combination to None. This will prevent the AMI aux output 1 from
activating during alarm. This output should only activate during a telephone page (if applicable).